Hot air sterilization and depyrogenation tunnels remove pyrogens from solutions, most commonly from injectable pharmaceuticals, by means of controlled exposure of glass containers to high temperature. Our tunnels are equipped with convection heat transfer and provide high production output with evenly and precise distribution of heat over glass vials, cartridges, syringes, and infusion containers.

Our depyrogenation tunnels are specially designed to be installed between a washing and a filling system. These high output tunnels counts on a precise temperature control and heat distribution to ensure full sterilization of glass containers before they are aseptically filled.

Tunnel

DT Series: Depyrogenation Tunnels for Glassware Containers

The DT Series of depyrogenation tunnels are designed for the continuous sterilization and depyrogenation of glassware containers such as, ampoules, vials, cartridges, and infusion bottles.

Sterilization is achieved in accordance to ISO 14644-1 requirements, by a laminar flow of filtered hot air, within an ISO 5 environment throughout the complete tunnel length.

The DT Series tunnels are composed of three main chambers: inlet chamber, hot chamber, and cooling chamber, with the possibility to add a fourth chamber for further cooling.

The perfect balance flow of airflow conditions insures the stability and uniform distribution of temperature offering safe and reproducible operations, with continuous in-process control and validation of the system.

  • Possibility of using air for the Inlet Chamber from either the room or from an external environment via a duct.
  • Heating Chamber composed of two insulated stainless steel shells.
  • Maximum hot air temperature of 350°C for energy saving and glass overheating prevention
  • Ability to process each container type with suitable time and temperature to ensure correct depyrogenation cycle
  • Additional dedicated fan provides the pressure control for the airflow balance in the Cooling Chamber
  • Inline connection to upstream and downstream equipment
  • Additional cooling chamber
  • Sterilization cooling section
  • Particle measuring inside the chamber
  • Continuous airglow measuring system
  • Automatic air pressure balance inside the tunnel for consistent positive pressure to avoid are back flow
  • Air speed monitoring and automatic adjustment by means of anemometris systems in all chambers
  • Automatic vial discharge at batch end
  • Remote assistance
  • Printer and SCADA interface for production data recording and management
  • Document packages for complete system validation